INCINERATORS

INCINERATORS

INCINERATORS

Due to actual shortage of Dumping Grounds & hence it has become necessary to dispose of the wastes by Incinerating. Incinerators are designed with most practical approach looking at Indian conditions. We do not boost of technical Collaboration but believe in technology suitable to Indian conditions. Be it a housing society, a hotel, a hospital, a slaughter house, poultry and even an industry. The waste is bound to be there. Incinerators are capable of incinerating all type of wastes. Be it solid, sludge, liquid or gas or even chemical waste. We also recommend & offer pollution control equipments as part of incineration system. A clean technology to ensure the elimination of your waste without provoking any atmospheric pollution. We have installed Incinerators throughout India in various Military Hospitals and other District Hospitals also in Andaman and Nicober Islands.
Enquiry Now

Sanitary Napkin Incinerator &
Paper Incinerator

A Sanitary Napkin Incinerator is an Automatic Sanitary Napkin Destroyer manufactured with a high rate of reliability proven through performance. It is the best solution for sanitary napkin disposing needs wherein the used napkins are converted into a sterile ash. It helps to instant disposal of a used napkins in a very Scientific and Hygienic Way.
Installation:-
Sanitary incinerators should be mounted approximately 1.2 m from ground level. A metal flue system is recommended, and should be at least 2.7 m in length to minimise the possibility of back draughts. Any bends in the flue should not be less than 120 degrees, but where bends tighter than this, or a long inclined horizontal flue run, is unavoidable, a fan should be used. Regular flue cleaning is essential, and suitable access should be provided. If the room in which the unit is to be sited also has an exhaust fan system, care must be taken to ensure that this does not pull fumes back down the flue.
Our various range of Napkin Incinerator models includes:
1. Nanonap – Upto 100 Napkins/day
2. Mininap – Upto 200 Napkins/day
3. Largenap – Upto 750 Napkins/day
Nanonap is the smallest Sanitary Napkin Incinerator in India and abroad.
The Dimension details are:
Height:- 400mm
Depth:- 175mm
Width:- 210mm
The dimension is adjustable. You need only a small corner of the toilet to install it.
General Specification:
1. Instant disposal of used Napkins in a very scientific and hygienic way.
2. Top Sliding Door for easy operation.
3. Low Weight for Easy and convenient to install inside the toilet and Wall Mountable.
4. Inside SS covering for maximum lifetime, Outside Mild Steel Metallic Spray painting.
5. The ash is collected in an Ash Collection tray or flush into drain through ash removal pipe at the bottom of the Incinerator.
6. Just Start and Forget. It Burns and Stops Automatically.
7. Complete burning of napkins only less than 5% ash per Napkin is generated.
Key Features:

  • It is safe ,clean, hygienic.
  • Fully automatic in operation.
  • Corrosion resistance steel case.
  • stainless steel chamber for long durability and longevity.
  • Low surface temperature.
  • Special sheathed wire element
  • Finished with powder coating, rust proof, moisture proof colour.
  • Easy to install
  • Power-on neon indicator.

The Sanitary Napkin Incinerator can be Used At

  • Public Toilets
  • Wash Rooms of Public Halls
  • School Girls Toilets
  • Refreshment of Shopping Malls
  • Colleges Ladies Toilet
  • Toilets of club Houses
  • Washrooms of Restaurants
  • Refreshment Area of Cinemas
  • Common in Ladies Hostels
  • Washrooms at Corporate Offices
  • Common Unit for Apartments
  • Toilets of Factories Where Ladies are working
  • Toilets of Railway Stations
  • Toilets of Library
  • Toilets of Air Ports
  • Toilets of Individual Bungalow
  • Toilets of Bus Stops
  • Toilets of Offices and Many more Places.
  • All The Rooms of Hotel.

Hospital and Industrial waste Incinerator

  • A range of standard incinerators able to destroy 5 to 500kg/hr.
  • A clean technology to ensure the elimination of your waste without provoking any atmospheric pollution.
  • A clean technology to ensure the elimination of your waste without provoking any atmospheric pollution.
  • A guaranteed elimination of waste coming from hospitals, Research Centres and all Contaminated waste consisted of syringes, bandages, cotton, dialysis, anatomical, Pieces, new virus and bacteria A ESB. Creutzfeld-Jacob diseases, contaminated bloody waste, medicaments, chemotherapy.
  • A security for environment thanks to total absence of
    smoke, dust and smells.
  • The reliability of the know-how with 3000 installations through the world .
  • A fully automatic cycle which does not require the
    presence of employees.

We also offer the following Equipments as options:-

  • Wet Scrubber
  • Droplet Separator
  • Venturi Scrubber

Waste Incinerator

There is actual shortage of Dumping Grounds & hence it has become necessary to dispose of the wastes by Incinerating.
Incinerators are designed with most practical approach looking at Indian conditions. We do not boost of technical Collaboration but believe in technology suitable to Indian conditions. Be it a housing society, a hotel, a hospital, a slaughter house, poultry and even an industry. The waste is bound to be there. How long we can have dumping grounds? A point to saturation is nearing. We have an answer is INCINERATOR.
Incinerators are capable of incinerating all type of wastes. Be it solid, sludge, liquid or gas or even chemical waste. We also recommend & offer pollution
control equipments as part of incineration system.
Incinerators are fully automatic in operation backed with burners; covers less space and the complete incineration process in smokeless due to multi chamber design. The waste material is incinerated by a main burner in the
primary chamber under controlled combustion conditions. The gases thus generated along with volatile materials are completely burned in the secondary chamber through after fire burner.
The complete incineration process takes place at around 900°C in primary chamber and 1000°C in secondary chamber. Various safeties are added up depending upon requirements to ensure a full proof system. Incineration is normally available ion ranges from 30kg per hr to 300kg per hr of different type of wastages, backed by gas and oil fired burners of highest combustion efficiency.
Various heat recovery system are also offered to salvage the heat being wasted through chimney.
Our wide range of waste management products includes:
General Waste Incinerator

  • Portable Electrical Incinerator
  • Medical / Bio Waste Incinerators
  • Animal Waste Incinerators
  • Sanitary Napkin Incinerator (Napkin)
  • Paper, Cd, Credit Card Shredders
  • Leaf / Garden Shredders
  • Exhaust pipe / Chimney

Sanitary Incinerators

Sanitary incinerators provide clean, hygienic and safe disposal of sanitary towels and small medical
dressings. A Sanfire unit is adequate for up to 40 users and can be connected to a single or common
flue system. Opening the charging door automatically switches on the heating element for a pre-set
incineration time. Ash residue is simply removed from the lockable drawer.
The robustly-build Sanitary incinerator is made of heavy-duty, corrosion-resistant sheet steel and has a stainless steel incineration chamber. For long life and trouble free use, it incorporates a special
sheathed wire element, and is easily wall-mounted with the integral keyhole-slotted lugs.
To aid installation an optional flue adapter, HE6768, and a 600mm flue, HE6767, are available.
Key Features:

  • Safe, clean and hygienic
  • Automatic operation
  • Heavy-duty corrosion resistant steel case
  • Stainless steel incineration chamber
  • Low surface temperature case
  • Special sheathed wire element
  • Power-on neon indicator
  • Easy to install
  • Ideal for disposal of sanitary towels and small medical dressings
  • Finished in Crisp White

Installaton:
Sanitary incinerators should be mounted with the top of the unit approximately 1.2 m from ground level. A metal flue system is recommended, and should be at least 2.7 m in length to minimise the possibility of back draughts. Any bends in the flue should not be less than 120 degrees, but where bends tighter than this, or a long inclined horizontal flue run, is unavoidable, the HE6772 accessory fan should be used. Regular flue cleaning is essential, and suitable access should be provided. If the room in which the unit is to be sited also has an extract fan system, care must be taken to ensure that this does not pull fumes back down the flue. Our free Advisory Service will provide information on common flue systems if required, please see back cover for details.
Our various range of Sanitary Incinerator models includes:

DIMENSIONS (mm)
Mode Height Depth Width Weight Kg
NANONAP 397 173 203 6.8
FIXING CENTRES (mm)
Mode A B C D E F G H
MININAP 295 76 203 40 73 26 11 78
Model: Capacity Loading at: Flue
Charge Users 230V Diameter
MAXINAP 4 40 550W 76
ACCESSORY: 13W IN LINE FAN UNIT
DIMENSIONS (mm)
Mode Height Depth Width
LARGENAP 203 183 165

Other services

View all services